OIP or RIP Transformer Bushing: What Should Buyers Check?
Compare oil and dry-core construction, mounting, maintenance and model-specific IEC 60137 test evidence before choosing a transformer bushing.

OIP condenser transformer bushing series; confirm ratings and service requirements by model.
Match the electrical duty and transformer or wall interface before requesting a design.
IEC 60137 applies to complete AC bushings; confirm edition and model-specific test evidence. Replacement fit requires drawing approval.
EONOVA provides sourcing solutions for condenser bushings based on customer specifications, equipment interfaces, and technical requirements. EONOVA – Your Sourcing Partner for High-Voltage Bushings from China.
Check the document model and revision; final dimensions require approved drawings.
| Model | Type | Rated voltage | Rated current | Total length | Creepage distance | Weight |
|---|---|---|---|---|---|---|
| BRDW-72.5/630-4 | Draw Lead | 72.5 kV | 630 A | 1885 mm | 2248 mm | 85 kg |
| BRDW-126/630-4 | Draw Lead | 126 kV | 630 A | 2498 mm | 3906 mm | 155 kg |
| BRLW-145/1250-4 | Draw Lead | 145 kV | 1250 A | 3280 mm | 5270 mm | 340 kg |
| BRLW-252/1600-4 | Bottom Connected | 252 kV | 1600 A | 4780 mm | 8595 mm | 700 kg |
| BRLW-252/3150-4 | Bottom Connected | 252 kV | 3150 A | 4935 mm | 8595 mm | 800 kg |
| BRDLW-550/2500-4 | Bottom Connected | 550 kV | 2500 A | 8340 mm | 18755 mm | 1900 kg |
| BRLW-800/1600-4 | Bottom Connected | 800 kV | 1600 A | 12075 mm | 30528 mm | 4900 kg |
| BRLW-1100/3150-3 | Bottom Connected | 1100 kV | 3150 A | 13930 mm | 33000 mm | 7200 kg |
| Model | Rated voltage | Rated current | Structure | Length | Creepage distance | Weight | Drawing |
|---|---|---|---|---|---|---|---|
| BRW-40.5/16000 | 40.5 kV | 16,000 A (16 kA) | Heavy Current OIP | 1,133 mm | 1,256 mm | 250 kg | Typical Design Page 1 (Heavy Current) |
| BRW-40.5/20000 | 40.5 kV | 20,000 A (20 kA) | Heavy Current OIP | 1,245 mm | 1,418 mm | 275 kg | Typical Design Page 1 (Heavy Current) |
| BRW-40.5/25000 | 40.5 kV | 25,000 A (25 kA) | Heavy Current OIP | 1,100 mm | 1,510 mm | 500 kg | Typical Design Page 1 (Heavy Current) |
| BRDLW-72.5/630-4 | 72.5 kV | 630 A | Draw Lead Type | 1,885 mm | 2,248 mm | 85 kg | Typical Design Page 2 (Draw Lead 72.5~170kV) |
| BRDLW-126/1250-4 | 126 kV | 1,250 A | Draw Lead Type | 2,910 mm | 3,906 mm | 200 kg | Typical Design Page 2 (Draw Lead 72.5~170kV) |
| BRDLW-145/1250-4 | 145 kV | 1,250 A | Draw Lead Type | 3,280 mm | 5,270 mm | 340 kg | Typical Design Page 2 (Draw Lead 72.5~170kV) |
| BRDLW-170/1250-4 | 170 kV | 1,250 A | Draw Lead Type | 3,435 mm | 5,270 mm | 340 kg | Typical Design Page 2 (Draw Lead 72.5~170kV) |
| BRLW-72.5/3150-4 | 72.5 kV | 3,150 A | Current Carrying Type | 2,660 mm | 2,248 mm | 170 kg | Typical Design Page 3 (Carrying 72.5~170kV) |
| BRLW-126/2500-4 | 126 kV | 2,500 A | Current Carrying Type | 3,335 mm | 4,050 mm | 200 kg | Typical Design Page 3 (Carrying 72.5~170kV) |
| BRLW-145/4000-4 | 145 kV | 4,000 A | Current Carrying Type | 3,530 mm | 5,270 mm | 220 kg | Typical Design Page 3 (Carrying 72.5~170kV) |
| BRLW-170/6300-4 | 170 kV | 6,300 A | Current Carrying Type | 3,870 mm | 5,270 mm | 270 kg | Typical Design Page 3 (Carrying 72.5~170kV) |
| BRDLW-252/630-4 | 252 kV | 630 A | Draw Lead Type | 4,580 mm | 8,995 mm | 570 kg | Typical Design Page 4 (Draw Lead 252~550kV) |
| BRDLW-363/1250-4 | 363 kV | 1,250 A | Draw Lead Type | 6,535 mm | 11,255 mm | 980 kg | Typical Design Page 4 (Draw Lead 252~550kV) |
| BRDLW-550/1250-4 | 550 kV | 1,250 A | Draw Lead Type | 8,180 mm | 18,755 mm | 1,800 kg | Typical Design Page 4 (Draw Lead 252~550kV) |
| BRLW-252/3150-4 | 252 kV | 3,150 A | Current Carrying Type | 4,935 mm | 8,595 mm | 800 kg | Typical Design Page 5 (Carrying 252~550kV) |
| BRLW-363/2500-4 | 363 kV | 2,500 A | Current Carrying Type | 6,475 mm | 11,255 mm | 950 kg | Typical Design Page 5 (Carrying 252~550kV) |
| BRLW-550/2500-4 | 550 kV | 2,500 A | Current Carrying Type | 8,340 mm | 18,755 mm | 1,980 kg | Typical Design Page 5 (Carrying 252~550kV) |
| BRLW-800/1600-4 | 800 kV | 1,600 A | UHV Current Carrying | 12,075 mm | 30,528 mm | 4,900 kg | Typical Design Page 6 (UHV 800~1100kV) |
| BRLW-1100/3250-3 | 1,100 kV (1100kV) | 3,250 A | UHV Current Carrying | 15,150 mm | 52,000 mm | 7,200 kg | Typical Design Page 6 (UHV 800~1100kV) |
| CRW-800/250-3 | 800 kV | 250 A | UHV OIP Wall Bushing | 17,000 mm | 21,000 mm | 9,200 kg | Typical Design Page 7 (Wall Bushing 800~1000kV) |
| CRW-1000/250-3 | 1,000 kV (1000kV) | 250 A | UHV OIP Wall Bushing | 17,340 mm | 27,000 mm | 9,600 kg | Typical Design Page 7 (Wall Bushing 800~1000kV) |
| CRWZ-1000(850)/250-3 | 1,000 kV (1000kV) | 250 A | UHV OIP Wall Bushing | 17,830 mm | 27,000 mm | 9,450 kg | Typical Design Page 7 (Wall Bushing 800~1000kV) |
| ±800kV DC Wall Bushing | ±800 kV DC / 1000 kV AC | 3,150 A | Composite Oil-SF6 Wall Bushing | 18,450 mm | ≥ 32,000 mm | Customized | Typical Design Page 8 (±800kV DC Wall) |
Dimensions, interfaces and replacement compatibility require approved drawings and technical review.
60+ Years Grid Heritage: Unrivaled longevity and proven field reliability across 100+ nations.
Class 10,000 Cleanroom Winding: Temperature & humidity strictly controlled (GB 50472-2008).
Full UHV 1100kV Track Record: 200+ units operating on 550kV DC and nearly 200 units on 800kV/1100kV UHV.
Extensive High-Speed Railway Supply: Over 2,000 bushings powering high-speed railway traction transformers.
Condenser-Type Field Control: Precision-wound capacitive cores control the radial and axial electric field distribution; field strength is verified against each model's design.
Ultra-Wide Voltage Coverage: Complete product range covering 11kV distribution, 72.5kV~550kV main grid, and 800kV~1100kV UHV transmission.
Heavy Current Capacity up to 40kA: Specialized heavy-current models engineered for large step-up transformers and industrial electric arc furnaces.
Metal flanges and seals require drawing review and model-specific oil-leakage acceptance.
Ultra-Low Partial Discharge: Partial discharge level strictly controlled ≤ 5 pC and dielectric loss factor tanδ ≤ 0.005.
Tailored Sourcing & Customization: Rapid customization of CT space lengths, lower oil-end dimensions, and terminals based on customer drawings.
Ultra-pure transformer oil with moisture < 10 ppm, breakdown voltage > 70 kV/2.5mm.
Flawless glaze with exceptional mechanical strength and pollution flashover resistance.
High-purity electrical kraft paper with aluminum foil capacitive screens, dried in high-vacuum autoclaves and impregnated with degassed transformer oil.
Available with high-strength brown/gray glazed porcelain housing or lightweight composite HTV silicone rubber housing for severe pollution and seismic environments.
Pressure-tight cast aluminum alloy mounting flanges with CNC machined sealing grooves; high-conductivity copper terminal boards with silver plating.
Enter your requirements and send them to our sales desk. If online sending is unavailable, you get an email draft instead.

Compare oil and dry-core construction, mounting, maintenance and model-specific IEC 60137 test evidence before choosing a transformer bushing.

Use IEC 60137 for applicable complete AC bushings; confirm the edition, rating, type and routine tests, and report identifiers for the offered model.

Identify voltage duty, field grading, moisture control, external insulation and altitude corrections in the project specification.