How to Specify GIS High-Voltage Test Equipment
Define test voltage, waveform, specimen capacitance, measurement background, space and safety interfaces before requesting a test-system design.

2,000A-10,000A High-Current Generator Test System for Switchgear, GIS & Conductor Temperature Rise Tests
Size the test source around the object, connection and test program.
IEC 60060-1 describes HV test techniques; IEC 60270 describes charge-based PD measurement. Confirm the apparatus test standard separately.
EONOVA supplies customized high-current generator sets, temperature rise test loops, and high-conductivity flexible connectors tailored to customer switchgear and GIS dimensions. EONOVA – Your Sourcing Partner for Electrical Testing Equipment from China.
Check the document model and revision; final dimensions require approved drawings.
| Parameter | Specification |
|---|---|
| Rated Output Current | 2,000 A ~ 10,000 A (Continuous adjustable) |
| Output Current Stability | ≤ ± 1.0% (Closed-loop automatic regulation) |
| Duty Cycle | Continuous (100% duty for long-duration temperature rise test) |
| Waveform Distortion | ≤ 3% (Standard sinusoidal power frequency current) |
| Temperature Acquisition | 16 ~ 64 Channels (PT100 / Thermocouple with auto logging) |
| Protection Functions | Overcurrent, overtemperature, phase loss, zero-start interlock |
| Applicable Equipment | GIS Busbars, High-Voltage Circuit Breakers, Disconnectors, Bus Ducts |
| Standard Compliance | GB/T 11022, IEC 62271-1, IEC 62271-203, DL/T 593 |
Dimensions, interfaces and replacement compatibility require approved drawings and technical review.
2,000A-10,000A High Continuous Output: Delivers sustained high current for prolonged thermal equilibrium and temperature rise verification.
High Current Stability & Low Distortion: Ultra-low impedance transformer design keeps output current stable and wave distortion ≤ 3%.
Closed-Loop Automatic Current Regulation: Automatically adjusts for test loop impedance shifts as conductors heat up.
Multi-Channel Temperature Data Logging: Synchronously logs conductor, joint, and enclosure temperatures with real-time curves.
Multi-Tier Safety Protection: Equipped with overcurrent, overheating, zero-start protection, and emergency interlocks.
High-permeability oriented silicon steel core with oversized oxygen-free copper secondary coils, ensuring high continuous thermal rating.
Specially designed silver-plated copper clamps with high clamping force to minimize contact resistance in high-current test loops.
Touchscreen industrial PC console with closed-loop PID current stabilization and multi-point temperature data acquisition.
Enter your requirements and send them to our sales desk. If online sending is unavailable, you get an email draft instead.

Define test voltage, waveform, specimen capacitance, measurement background, space and safety interfaces before requesting a test-system design.

Use IEC 60137 for applicable complete AC bushings; confirm the edition, rating, type and routine tests, and report identifiers for the offered model.

Identify voltage duty, field grading, moisture control, external insulation and altitude corrections in the project specification.