HCTSLow-Voltage High-Current Output
High-Current Test System
Review model drawings and test evidence
GIS Testing & Diagnostic Equipment

High-Current Test System

2,000A-10,000A High-Current Generator Test System for Switchgear, GIS & Conductor Temperature Rise Tests

Rated VoltageLow-Voltage High-Current Output
Rated Current2000A ~ 10000A (Up to 10kA)
Insulation TypeDry-Type Transformer / AC High-Current Loop
Catalog standardGB/T 11022 / IEC 62271-1 / IEC 62271-203 / DL/T 593
PD requirementConfirm by model
Test evidenceRequest with RFQ

Buyer requirement checklist

Size the test source around the object, connection and test program.

  • Test object, capacitance and required voltage waveform
  • Frequency range, duty cycle and site/lab use
  • PD sensitivity, measurement and calibration needs
  • GIS connection, power supply and safety envelope

IEC 60060-1 describes HV test techniques; IEC 60270 describes charge-based PD measurement. Confirm the apparatus test standard separately.

Product Technical Overview

The High-Current Test System is designed to provide high-current output for testing electrical equipment and verifying its performance under specified current conditions. Featuring high output current capability and stable current regulation, the system supports reliable and repeatable testing. It can also be equipped with safety protection functions, including overcurrent and overtemperature protection, to support safe and convenient operation. Key Features: • Large output current capability (2,000A – 10,000A), meeting the test requirements of different equipment • High current stability, ensuring the accuracy of test results • Easy to operate with overcurrent protection, overheating protection, and other safety functions • Closed-loop automatic current stabilization for extended thermal equilibrium tests • Suitable for temperature-rise verification on GIS, circuit breakers, and heavy busbar conductors
// CUSTOM SOURCING & ENGINEERING SPEC

EONOVA supplies customized high-current generator sets, temperature rise test loops, and high-conductivity flexible connectors tailored to customer switchgear and GIS dimensions. EONOVA – Your Sourcing Partner for Electrical Testing Equipment from China.

Compatible Substation Apparatus

High-voltage switchgear and GIS temperature-rise testsCircuit breakers, disconnectors, and earthing switches continuous current rating testsHeavy current busbars, conductors, and bolted electrical jointsCurrent transformers (CT) primary injection testing
Engineering Inquiry Draft

Request Quotation for High-Current Test System

Enter your requirements and send them to our sales desk. If online sending is unavailable, you get an email draft instead.

Sales Director (Alex): +91 9319809969 · sales@eonovaintl.com

High-Current Test System: FAQ

What voltage and current range does the High-Current Test System cover?
Catalogue voltage range: Low-Voltage High-Current Output; current range: 2000A ~ 10000A (Up to 10kA). Confirm the rating of the specific model and drawing.
What insulation or construction is used?
Dry-Type Transformer / AC High-Current Loop.
Which standards are referenced?
Catalogue standard reference: GB/T 11022 / IEC 62271-1 / IEC 62271-203 / DL/T 593. Request type-test evidence for the specific model.
Is a product catalogue available?
Yes. GIS High-Voltage Testing Equipment Catalog.pdf can be downloaded from this page.