HomeProductsGIS Testing & Diagnostic EquipmentMetal-Clad Lightning Impulse Generator
MIG900kV ~ 4200kV
Metal-Clad Lightning Impulse Generator
Review model drawings and test evidence
GIS Testing & Diagnostic Equipment

Metal-Clad Lightning Impulse Generator

High-energy metal-clad lightning impulse generator generating 1.2/50µs lightning and 250/2500µs switching impulses up to 4200kV.

Rated Voltage900kV ~ 4200kV
Rated CurrentNominal Energy 45kJ ~ 315kJ
Insulation TypePressurized SF6 Metal-Clad Enclosed
Catalog standardIEC 60060-1 / IEC 60060-2 / GB/T 16927.1
PD requirementConfirm by model
Test evidenceRequest with RFQ

Buyer requirement checklist

Size the test source around the object, connection and test program.

  • Test object, capacitance and required voltage waveform
  • Frequency range, duty cycle and site/lab use
  • PD sensitivity, measurement and calibration needs
  • GIS connection, power supply and safety envelope

IEC 60060-1 describes HV test techniques; IEC 60270 describes charge-based PD measurement. Confirm the apparatus test standard separately.

Product Technical Overview

EONOVA MIG Series metal-clad lightning impulse generators utilize high-pressure SF6 gas as the primary insulating medium inside a grounded horizontal or vertical steel cylinder. By minimizing loop inductance and external electromagnetic radiation, it delivers standardized full-wave, chopped-wave, and switching impulses for ultra-high voltage GIS development and type testing.

Compatible Substation Apparatus

GIS Switchgear Impulse Withstand & Margin TestsTransformer & Bushing Lightning Impulse QualificationUltra-High Voltage Insulator String TestingElectromagnetic Pulse Research Centers
Engineering Inquiry Draft

Request Quotation for Metal-Clad Lightning Impulse Generator

Enter your requirements and send them to our sales desk. If online sending is unavailable, you get an email draft instead.

Sales Director (Alex): +91 9319809969 · sales@eonovaintl.com

Metal-Clad Lightning Impulse Generator: FAQ

What voltage and current range does the Metal-Clad Lightning Impulse Generator cover?
Catalogue voltage range: 900kV ~ 4200kV; current range: Nominal Energy 45kJ ~ 315kJ. Confirm the rating of the specific model and drawing.
What insulation or construction is used?
Pressurized SF6 Metal-Clad Enclosed.
Which standards are referenced?
Catalogue standard reference: IEC 60060-1 / IEC 60060-2 / GB/T 16927.1. Request type-test evidence for the specific model.