HomeProductsGIS Testing & Diagnostic EquipmentGIS On-Site Resonance Test & Diagnostic System
GRDS300kV ~ 1250kV
GIS On-Site Resonance Test & Diagnostic System
Review model drawings and test evidence
GIS Testing & Diagnostic Equipment

GIS On-Site Resonance Test & Diagnostic System

Modular mobile series resonance withstand system with high-precision SF6 quantitative leakage detection (0.01 ppm).

Rated Voltage300kV ~ 1250kV
Rated CurrentOutput Current 2A ~ 10A
Insulation TypeVariable Frequency Resonance & Optical SF6 Sensor
Catalog standardIEC 60270 / IEC 62271-203 / DL/T 555
PD requirementConfirm by model
Test evidenceRequest with RFQ

Buyer requirement checklist

Size the test source around the object, connection and test program.

  • Test object, capacitance and required voltage waveform
  • Frequency range, duty cycle and site/lab use
  • PD sensitivity, measurement and calibration needs
  • GIS connection, power supply and safety envelope

IEC 60060-1 describes HV test techniques; IEC 60270 describes charge-based PD measurement. Confirm the apparatus test standard separately.

Product Technical Overview

Tailored for substation on-site handover tests and energized preventive maintenance, this integrated diagnostic suite includes a high-efficiency variable-frequency series resonance power supply, modular GIS SF6 testing tanks, ultrasonic and UHF partial discharge analyzers, and optical SF6 gas leak locators.

Compatible Substation Apparatus

Substation On-Site Handover & Acceptance TestsEnergized GIS Partial Discharge Ultrasonic InspectionEnvironmental SF6 Trace Leakage QuantificationAnnual Grid Preventive Maintenance
Engineering Inquiry Draft

Request Quotation for GIS On-Site Resonance Test & Diagnostic System

Enter your requirements and send them to our sales desk. If online sending is unavailable, you get an email draft instead.

Sales Director (Alex): +91 9319809969 · sales@eonovaintl.com

GIS On-Site Resonance Test & Diagnostic System: FAQ

What voltage and current range does the GIS On-Site Resonance Test & Diagnostic System cover?
Catalogue voltage range: 300kV ~ 1250kV; current range: Output Current 2A ~ 10A. Confirm the rating of the specific model and drawing.
What insulation or construction is used?
Variable Frequency Resonance & Optical SF6 Sensor.
Which standards are referenced?
Catalogue standard reference: IEC 60270 / IEC 62271-203 / DL/T 555. Request type-test evidence for the specific model.