How to Specify GIS High-Voltage Test Equipment
Define test voltage, waveform, specimen capacitance, measurement background, space and safety interfaces before requesting a test-system design.

300kV-1250kV Power Frequency Withstand Voltage & Partial Discharge Test System for High-Voltage Insulators & GIS Components
Size the test source around the object, connection and test program.
IEC 60060-1 describes HV test techniques; IEC 60270 describes charge-based PD measurement. Confirm the apparatus test standard separately.
EONOVA supplies custom-tailored power frequency test fixtures, test tanks, and automated testing arrangements based on customer insulator drawings and capacity requirements. EONOVA – Your Sourcing Partner for High-Voltage Testing Equipment from China.
Check the document model and revision; final dimensions require approved drawings.
| Parameter | Specification |
|---|---|
| Rated Test Voltage | 300 kV ~ 1250 kV (Power Frequency AC 50/60 Hz) |
| System PD Background | ≤ 2 pC (at 100% rated test voltage) |
| Insulating Medium | SF6 Gas (Operating pressure 0.35 ~ 0.50 MPa) |
| Tested Components | GIS Basin Insulators, Insulating Cylinders, Operating Rods, Bushing Shells |
| Tooling Fixtures | FEA Electric Field Optimized Custom Test Jigs & Quick-Access Chambers |
| Control & Acquisition | Automated PLC console with touch screen, automatic ramp, and PD measurement |
| Safety Protection | Overvoltage, overcurrent, flashover breakdown trip, SF6 pressure interlock |
| Standard Compliance | GB/T 16927.1, IEC 60060-1, IEC 62271-203, DL/T 555 |
Dimensions, interfaces and replacement compatibility require approved drawings and technical review.
300kV-1250kV Full UHV Range: Specialized test vessels and busbar interfaces supporting insulation tests up to 1250kV AC.
Electric Field Simulation Optimized Tooling: HV shielding and stress-grading electrodes customized per test object, optimized by 3D field simulation to reproduce the field inside GIS.
Ultra-Low PD Background ≤ 2 pC: Completely metal-enclosed layout ensuring ultra-sensitive partial discharge measurement.
High-Efficiency Clamping: Rapid mechanical clamping mechanism and quick-access door shorten cycle times in mass production.
Application Record: In operation at insulator and GIS manufacturers including Shenma, XD and Sieyuan.
Welded pressure enclosure for designs up to 0.5 MPa; confirm design pressure, leak-test method and acceptance limit for the model.
Mirror-polished aluminum shielding electrodes designed via finite-element electric field simulations to suppress corona and stray discharge.
Integrated PLC and high-precision AC peak voltmeter with automatic voltage boost, timing, flashover trip, and gas pressure interlock.
Enter your requirements and send them to our sales desk. If online sending is unavailable, you get an email draft instead.

Define test voltage, waveform, specimen capacitance, measurement background, space and safety interfaces before requesting a test-system design.

Use IEC 60137 for applicable complete AC bushings; confirm the edition, rating, type and routine tests, and report identifiers for the offered model.

Identify voltage duty, field grading, moisture control, external insulation and altitude corrections in the project specification.