OIP or RIP Transformer Bushing: What Should Buyers Check?
Compare oil and dry-core construction, mounting, maintenance and model-specific IEC 60137 test evidence before choosing a transformer bushing.

Key functional capacitive grading core determining dielectric performance and long-term reliability of 52kV-800kV RIP bushings
Define the core as an engineered subcomponent with its own interface and acceptance plan.
IEC 60137 covers complete AC bushings, not standalone RIP cores; agree core acceptance tests separately.
For RIP condenser cores, share dimensional drawings, capacitance requirements and electric-field constraints. Confirm design responsibility, manufacturing site and test scope with the quoted supplier.
| Parameter | Specification |
|---|---|
| Rated Voltage Class | 52kV ~ 800kV (52, 72.5, 126, 145, 252, 363, 550, 800 kV) |
| Rated Current | 630 A ~ 5,000 A (Draw-lead or direct solid rod type) |
| Insulation Technology | Resin-Impregnated Paper (RIP) Capacitive Condenser Core |
| Partial Discharge (PD) | ≤ 2 pC at 1.05 Um / √3 (Far superior to IEC 60137 limit) |
| Dielectric Dissipation Factor | tanδ ≤ 0.0035 (0.35%) at ambient temperature |
| Glass Transition Temp | Tg ≥ 120 °C (High-Tg modified anhydride epoxy matrix) |
| Lightning Impulse Withstand (BIL) | Up to 2100 kV (depending on bushing rated voltage class) |
| Switching Impulse Withstand (SIL) | Up to 1600 kV (for 550kV & 800kV classes) |
| Thermal Insulation Class | Class E (120 °C) / Class B (130 °C) |
| Standard Compliance | IEC 60137, IEEE C57.19.01, GB/T 4109, DL/T 417 |
Dimensions, interfaces and replacement compatibility require approved drawings and technical review.
Precision-engineered capacitive grading structure with micron-level foil alignment for uniform electric field distribution.
Specialized high-vacuum resin impregnation and automated step-curing preventing micro-voids and partial discharge.
High-Tg modified epoxy resin matrix offering superior thermal endurance and mechanical integrity under cantilever stresses.
Dry-type solid insulation with no insulating oil or SF6 gas, avoiding oil-leakage and gas-related hazards in the insulation.
Broad voltage coverage from 52kV to 800kV, tailored to specific customer flange, conductor, and insulator dimensions.
Agree routine partial-discharge and dielectric-loss tests for the quoted complete bushing and core scope.
Special electrical-grade high-purity crepe insulating paper with low ash content and high dielectric breakdown strength.
Low-viscosity, high-purity epoxy anhydride casting resin system with high glass transition temperature (Tg ≥ 120°C).
Smooth-edged conductive aluminum capacitor foil for electric field grading, processed without burrs to prevent field concentration.
Compatible with solid copper rods, hollow tubes, or draw-lead conductors with anti-loosening and mechanical lock design.
Enter your requirements and send them to our sales desk. If online sending is unavailable, you get an email draft instead.

Compare oil and dry-core construction, mounting, maintenance and model-specific IEC 60137 test evidence before choosing a transformer bushing.

Review field grading, dimensions, impregnation, curing and model-specific dielectric tests when sourcing RIP condenser cores.